HE244 Hall sensor

High Precision Analog Hall Effect Sensor

HE244 Hall Sensor Series

Leads

Ferrite core

Air gap

Hall Effect sensor

A common application is magnetic field measurements in thin airgaps

HE244S

AST244S

Fine pads suitable for soldering or microwelding

Size: 3,0 x 5,0 mm

Max thickness 0,80 mm

AST244T / AST244HT

Standard or high temp wires.

20 cm pair-twisted wires as standard.

Size: 3,0 x 5,0 mm

Max thickness 0,80 mm

IMG00443-01

New product releases:

HE214SH

AST214SH

Extra thin SMD component

Max thickness 0,60 mm

Available sizes:

2,0 x 2,0 mm

From spring 2021 also 3,0 x 3,0 mm

(size as HE144SH)


AST 214T

AST 244P

Pin version

Body size: 2,2 x 3,1 mm

Total length 14,3 mm

Pitch 1,27 mm

Max thickness 0,70 mm

AST 214T

AST214T / HE214HT

Extra thin wired component.

Standard or high temp wires.

20 cm pair-twisted wires as standard.

Available sizes:

2,0 x 5.0 mm, also 3,0 x 5,0 mm)

Max thickness 0,60 mm

Hall sensor array

AST 244 5-chip Array

5-chip array with

1 mm pitch between sensors

Size: 7 x 8 mm

Max thickness: 1,2 mm

15 cm standard wires

(Custom length wires also possible)


Typical Applications:

  • Measuring precise homogenous fields
  • Precise current and power sensors
  • Measure both strongly magnetized metals and remanent magnetism with one sensor
  • Measurements in small metal, magnet and ferrite airgaps
  • Low DC current in strong AC currents, for example in windmills where only a limited DC current is allowed to be fed into the net


Application notes:


An easy way to do Hall sensor measurements

In the HE244 Hall sensor, the high resolution, combined with the ability to detect small changes in very strong magnetic fields, moves your measurements into the ppm range.


The HE244 hall sensor series is ultra-stable

  • Very wide range from a few µ-Tesla up to 10 Tesla and above
  • Measures both positive and negative fields with very high precision
  • Very low noise
  • Very wide temperature range; a high temperature version up to +250°C/+480°F is also available
  • Very low temperature coefficient
  • Very low offset
  • Ultra-low drift as well as long term drift
  • Ultra-low PHE (Planar Hall Effect) Error.

Z-field measurements show no X- and Y-field errors

  • X-ray resistant


For dynamic, low noise measurements, we recommend sensor currents of 2 mA or lower for the HE244. For higher output, sensor currents up to 10 mA can be used. As a rule of thumb, the HE244 series gives an output of 0,2 V/T at 2 mA sensor current.